Hanbon
Bio-Lab¢ç Laboratory Chromatography System
Bio-Lab¢ç Laboratory Chromatography SystemÀº ÇѺ»(Hanbon)¿¡¼ µ¶ÀÚÀûÀ¸·Î °³¹ßÇÑ ½Å¼Ó¼º ¹× ½Å·Ú¼ºÀÌ ÀÖ´Â °íÈ¿À² Automatic Chromatography ÀåÄ¡ÀÔ´Ï´Ù. ÀÌ ½Ã½ºÅÛÀº ¸¶ÀÌÅ©·Î±×·¥ºÎÅÍ ±×·¥ ´ÜÀ§ÀÇ »ý¹° ºÐÀÚµéÀ» ½Å¼ÓÇÏ°Ô Á¤Á¦ÇÏ´Â µ¥ »ç¿ëµÉ ¼ö ÀÖÀ¸¸ç, Protein, Polypeptide, Nucleic Acids µî°ú °°Àº »ý¹° ºÐÀÚµéÀ» ´ë»óÀ¸·Î ÇÕ´Ï´Ù. ½Ã½ºÅÛÀº ¸ðµâÇü ¼³°è¿Í Áö´ÉÇü ¼ÒÇÁÆ®¿þ¾î¸¦ È°¿ëÇÏ¿© ´Ù¾çÇÑ Chromatography columnsÀÇ »ç¾çÀ» Á¶ÇÕÇÏ¿©, ¿¬±¸½Ç¿¡¼ ´Ù¾çÇÑ »ý¹° ºÐÀÚ Á¤Á¦ ¿ä±¸¸¦ ÃæÁ·½Ãų ¼ö ÀÖ½À´Ï´Ù.
Ư¡
- °í¼º´É ½Ã½ºÅÛ ÆßÇÁ, °ËÃâ±â, ¹Í¼ µî ´Ù¾çÇÑ Á¦¾î ¹ëºê´Â ¶Ù¾î³ Á¤È®µµ¿Í ¹Ýº¹¼ºÀ» Á¦°øÇÏ¿© ±â´ëÇÏ´Â °á°ú¸¦ ½Å¼ÓÇÏ°Ô ¾òÀ» ¼ö ÀÖµµ·Ï º¸ÀåÇÕ´Ï´Ù.
- ¸ðµâÇü ¼³°è´Â ½Ã½ºÅÛ À¯Áöº¸¼ö¸¦ ¿ëÀÌÇÏ°Ô Çϸç, °·ÂÇÑ ½Ã½ºÅÛ ¼ÒÇÁÆ®¿þ¾î¿Í °áÇÕÇÏ¿© ´ÙÁß »ç¿ëÀÚ ·Î±×ÀÎ ¸ðµå¸¦ ÃæÁ·½ÃÅ°±â À§ÇÑ ¾÷±×·¹À̵带 ½ÇÇöÇÒ ¼ö ÀÖ½À´Ï´Ù.
- »ùÇðú Á¢ÃËÇÏ´Â ¸ðµç ÆÄÀÌÇÁ¶óÀÎ ¹× ±¸¼º ¿ä¼ÒÀÇ ¿ì¼öÇÑ »ý¹°ÇÐÀû ÀûÇÕ¼º, ±×¸®°í protein activityÀÇ ¿ÏÀüÇÑ º¸È£¸¦ Á¦°øÇÕ´Ï´Ù.
- ÇØ´ç ¼ÒÇÁÆ®¿þ¾î´Â GLP/GMP ±ÔÁ¤ ¹× FDA 21 CFR Part 11 ¿ä±¸»çÇ×À» ÁؼöÇÕ´Ï´Ù.
- ÇØ´ç ¼ÒÇÁÆ®¿þ¾î´Â ¿ÏÀüÇÑ ±â´É, ¿ì¼öÇÑ »ç¿ëÀÚ °æÇèÀ» Ư¡À¸·Î ÇÏ¿©, ´ÙÁß ·¹º§ »ç¿ëÀÚ ±ÇÇÑ°ú ¿ÏÀüÇÑ °¨»ç ÃßÀû ¿ä±¸ »çÇ×À» ÃæÁ·½Ãų ¼ö ÀÖ½À´Ï´Ù.
Model No. |
Bio-Lab 30 |
Bio-Lab 100 |
Bio-Lab 300 |
System Pump |
Binary piston pump, PEEK, titanium alloy or 316 L stainless steel, good biological compatibility; pump head self-washing functionprevents pollution and salting out, and electronic pressure fluctuation compensation measures provide excellent gradient accuracy
and repeatability for lab chromatography system to ensure the reproducibility. |
Flow Rate Range(ml/min) |
0~30 |
0~100 |
0~300 |
Pump-max pressure(MPa) |
¡Â30 |
¡Â20 |
¡Â15 |
System-max pressure |
1.3Mpa£¨Customized 0-8Mpa£© |
Flow Rate Accuracy |
¡¾1.0% |
Gradient Model |
Linear, isocratic, and stepwise elution gradients which modify the gradient ratio online |
UV Detector |
Two channel UV detector, deuterium lamp (standard), tungsten lamp (optional) |
Wavelength Range(nm) |
190-400 |
Absorbance Range(Au) |
-5~5 |
Wavelength Accuracy |
¡¾1nm |
Conductivity Detection Range |
1~999 mS/cm£¬error of ¡¾3% |
pH Detection Range |
0~14£¬error of ¡¾0.05pH£¬ 0.01pH Resolution |
Valve |
Standard: 2-channel inlet valve*2; Column position valve; Injection valve; 2-channel collection valve |
Sensor |
Air sensor and Pressure transmitter |
Mixer(ml) |
0.6¡¢2¡¢5¡¢10 |
Software Workstation |
Bio-lab¢çChromatographic work station |
Power(kw) |
1 |
1 |
1 |
Dimensions£¨cm£© |
450*585*604 |
450*585*604 |
620*550*675 |
Joint specification |
1/16",1/8" |
1/16",1/8" |
1/8",1/4",3/16" |
Detector |
|
UV Detector |
Ecom four-channel detector£¬200-800nm |
Differential Refractive Detector |
RI-501¡¢RI-502¡¢RI-504 |
Sample Pump | |
Flow Rate Range(mL/min) |
High accuracy piston pump
0-30/0-100/0-300 |
Sensor | |
Air sensor |
Optional dual branch Air sensor |
Pressure Sensor |
Optional post-column Pressure Sensor |
Valve | |
Inlet Valve |
4- channel inlet valve or 8- channel is optional |
Multifunctional Column |
4-channel column position valve or 6-channel or |
Position Valve |
8-channel is optional |
Outlet Valve |
4- channel outlet valve or 8- channel is optional |